In Toyota A340E/H Early (Type 1) units (Figure 1), the secondary pressure regulator valve receives regulated line fluid pressure from the main pressure regulator valve and routes it to the converter and lubrication circuits. The continual oscillation of the steel valve within the cast aluminum sleeve creates wear, allowing this valuable fluid pressure to exhaust and resulting in converter complaints, burnt apply components and lube-related failures. Sonnax oversized secondary pressure regulator valve kit 97741-17K restores proper hydraulic clearance and includes an O-ringed end plug to positively seal the balance pressure circuit. Valve is hardcoat anodized to reduce wear O-Ringed end plug positively seals the balance pressure circuit
Valve Kit; Includes OS Valve, End Plug; Required: T-VB-FIX, T-F-39741-TL11